As part of our specialized repair and diagnostic services, we offer comprehensive testing of NVDs using the ANV 126/A Test Equipment. Our service covers thorough assessment of low and high light resolution, measurement of system current, collimation accuracy, low battery indication response, gain levels, and identification of black spots within the optical system.
Our repair services include the use of this kit to ensure the internal environment of NVDs is properly maintained. This kit is specifically designed to purge nitrogen into NVD housings, effectively displacing moisture and preventing internal fogging or condensation. Post-repair purging is a critical step to preserve optical clarity and enhance the longevity and reliability of NVDs, especially in highhumidity or variable temperature conditions.
Our repair and calibration services include the use of the TS-3895A/UV Test Equipment, a precision diagnostic platform for evaluating the operational health of Night Vision Devices (NVDs). This test bench enables accurate testing of key functional parameters, including low and high light resolution, system current, collimation, low battery indication, and overall power integrity
This advanced platform is used to verify and adjust key optical parameters such as system resolution, infinity focus, diopter focus, and sight parallax. These checks ensure the device is precisely calibrated and aligned, restoring it to full operational capability. Post-repair, each unit undergoes this final stage of testing to guarantee accuracy, clarity, and optimal field performance.
We utilize the Precision Optical Test Bench L360N as part of our repair and verification services for NVGs. This high-accuracy optical platform is used to assess critical parameters such as image resolution, collimation alignment, infinity focus, and close focus functionality. After any repair or adjustment, NVGs are tested on this bench to ensure they meet precise optical performance standards.
Advanced unit is designed to perform essential functions such as nitrogen purging, pressure verification and leak detection. Our service ensures that after repair, the equipment is properly sealed, pressure-stable, and free of leaks, maintaining its operational reliability and extending its service life under demanding conditions.
Precision testing platform enables accurate assessment of key optical and electrical characteristics including gain, maximum output, luminance, equivalent background illumination (EBI), and overall image quality. Following any repair or refurbishment, Image Intensifier Tubes are thoroughly tested on this equipment to ensure they meet operational standards and deliver optimal performance .
This test bench is specifically designed to measure system gain and system current, ensuring that NVGs operate within specified parameters. By verifying these essential functions post-repair, we ensure the devices deliver optimal brightness amplification and power efficiency, maintaining their reliability